Technical data
Protection degree IP45 |
Nominal voltage (V AC) 110–240 V AC |
Operating voltage (V) 4.5 V DC |
Mains frequency (Hz) 50–60 Hz |
Flow pressure (bar) - min. to max. 1–8 bar |
Test pressure, water (bar) - max. 16 bar |
Test pressure, air / inert gas (bar) - max. 3 bar |
Operating temperature, water (°C) - max. 30 °C |
Flow rate at 1 bar without flow limiter (l/s) 0.3 l/s |
Flow rate at 1 bar with flow limiter (l/s) 0.18 l/s |
Calculated flow rate (l/s) 0.23 l/s |
Relative humidity (%) - min. to max. ≤ 100 % |
Minimum flow pressure for calculated flow rate (bar) 1 bar |
Interval flush, adjustment range (h) 1–168 h |
Interval flush, factory setting (h) 24 h |
Interval flush time, adjustment range (s) 3–180 s |
Interval flush time, factory setting (s) 5 s |
Detection time, adjustment range (s) - min. to max. 3–15 s |
Detection time, factory setting (s) 7 s |
Flush time, adjustment range (s) 1–15 s |
Flush time, factory setting (s) 7 s |
Application purposes
Characteristics
Scope of delivery
Type 01 cover plate, IR window, round
Mounting frame
Infrared control, premounted on mounting frame
Solenoid valve
Power supply unit
Fastening material
Documents
Films
Spare parts
Urinal flush controls with electronic flush actuation, battery / mains operation
Urinal flush controls with electronic flush actuation, battery / mains operation
2009 -
# | Art. no. | Description | Replaced by | Replacement for | Remarks |
---|---|---|---|---|---|
6 | 243.137.00.1 | Geberit set of alkaline batteries, type AA, 1.5 V (2 pc.) | (commercially available) | ||
8 | 241.943.00.1 | Geberit mounting frame, horizontal | For cover plate Tango | ||
9.2 | 243.327.00.1 | Geberit flow regulator 14 l/min, for urinal flush control | |||